Winter heating dries indoor air, so humidifiers come out of closets every November. They are simple machines, but the type you choose decides how much cleaning it needs and whether you'll be dusting fine white powder off the furniture. Standing water also needs regular attention. Here is how the main types differ and how to look after each one, based on guidance from the US Environmental Protection Agency (EPA), the Consumer Product Safety Commission (CPSC) and manufacturers' manuals.

The main types

TypeHow it worksWhite dust?Main upkeep
UltrasonicA vibrating plate turns water into a fine cool mistYes with tap water: minerals go into the airDaily water change, regular descaling; use low-mineral water
Impeller (cool mist)A spinning disc flings water into dropletsYes, similar to ultrasonicAs ultrasonic
EvaporativeA fan blows air through a wet wick or padNot expected to release much; minerals stay in the wickReplace the wick or pad on schedule
Steam / warm mistWater is heated and released as vaporNot expected to release muchDescale the heating chamber; keep away from children
Whole-house (central)Built into the furnace ductworkUsually evaporative or steamWater panel or canister replacement, often by season

The EPA says ultrasonic and impeller units disperse the most microorganisms and minerals from their tanks, while evaporative and steam units release fewer, though all of them can grow microbes in standing water if neglected (EPA: use and care of home humidifiers). That doesn't make ultrasonic models a bad choice; they're quiet and need no wicks. It means the water you put in and the cleaning routine matter more.

Honeywell HWM445B Easy-to-Care Filter Free Warm Mist Humidifier
No wick to buy, little white dustHoneywell HWM445B Easy-to-Care Filter Free Warm Mist Humidifier
$69.99 $77.99 · Sylvane
A warm mist humidifier with no filter, a 1.5-gallon top-fill tank, a five-setting humidistat and automatic shut-off when the tank runs dry, per Sylvane. The EPA doesn't expect steam models to release much mineral dust, but the water is heated and the chamber still needs descaling. Not for: homes with toddlers, where hot water is a burn risk.
See it at Sylvane

White dust and which water to use

That fine white film on shelves near an ultrasonic humidifier is minerals from tap water. The CPSC notes the dust can contain particles small enough to be inhaled and that minerals also form scale inside the tank, which gives bacteria and fungi a surface to grow on (CPSC: dirty humidifiers). The EPA's guidance on water is clear:

  • Distilled water is the best option, because distillation removes the most minerals.
  • Deionized or reverse-osmosis water is also low in minerals, though generally less so than distilled.
  • "Spring," "artesian" or "mineral" bottled water is not demineralized, so it won't help.
  • Demineralization cartridges vary in how well they work. If white dust still appears, the cartridge isn't keeping up. In hard-water areas, the EPA notes that distilled water can cost less than cartridges.

Evaporative models sidestep most of this: minerals are left behind in the wick, which is why the wick hardens and needs replacing.

The cleaning schedule

WhenWhat to doSource
Every dayEmpty the tank, wipe surfaces dry and refill with fresh waterEPA; CPSC
Every third dayEmpty and scrub the tank with a brush to remove scale and film, then wipe dryEPA
WeeklyDescale and disinfect, as separate steps, following your manualHoneywell manual
Every 30–60 daysReplace the wick on a portable evaporative unit (sooner with hard water)Honeywell manual
Once or twice a seasonReplace a whole-house water panelAprilaire
End of seasonDrain, clean, dry every part completely and store dryEPA; CPSC

Always unplug the humidifier before cleaning it or changing the water; both agencies say so.

How to descale and disinfect

Follow your own manual first, because materials differ. As a worked example, Honeywell's HEV620 manual recommends weekly cleaning and splits it into two separate jobs (Honeywell HEV620 owner's manual):

  1. Scale removal: take the wick out, pour at least 3 cups of undiluted white vinegar into the tank, let it drain into the base and soak for 20 minutes, wipe loosened minerals away, then rinse until the vinegar smell is gone.
  2. Disinfecting: mix 1 teaspoon of bleach in 1 gallon of water, soak for 20 minutes, empty and rinse thoroughly. The manual warns that a stronger mix can damage the unit.

Two cautions apply to every model. Never combine the two steps, because mixing bleach and vinegar releases chlorine gas. And rinse well after any cleaner: the CPSC specifically says to rinse the tank so you don't breathe in cleaning chemicals. Where a manual gives no disinfecting method, the EPA suggests 3% hydrogen peroxide on surfaces that touch water, followed by several rinses. Use a soft brush, and avoid scratching the tank or soaking the motor base.

Wicks, pads and water panels

An evaporative wick traps minerals as water evaporates from it. Over time it stiffens, may smell, and puts out less moisture. Honeywell recommends replacing the wick in its portable units every 30 to 60 days depending on water quality and use, and more often with hard water. Its manual says not to clean wicks with vinegar, soap or chemicals; soaking in cool water loosens minerals, but only as a stopgap until a new filter arrives.

Whole-house humidifiers use a water panel in the furnace ductwork. Aprilaire recommends replacing its 10, 12 and 35 water panels once a year or heating season, and its 45 panel twice a season (Aprilaire replacement parts). Steam whole-house units use a canister that is replaced as minerals build up; check the manual for your model. Always match a replacement wick, pad or panel to your model number.

Vornado Humidifier Wick 2-Pack (MD1-0002)
Vornado evaporative ownersVornado Humidifier Wick 2-Pack (MD1-0002)
$17.99 · Sylvane
Two replacement wicks, part MD1-0002 (same as MD1-0001), which Sylvane lists for Vornado evaporative humidifiers including the Evap1, Evap3, Model 30, Model 50 and EV3. Not for: other brands, or Vornado models not on the list; check the part number in your manual.
See it at Sylvane

Don't overdo the humidity

More moisture is not always better. The CPSC suggests keeping indoor relative humidity between 30% and 50% where possible and warns that levels above 60% let moisture condense on surfaces where bacteria and fungi grow. The EPA says not to exceed 50%. If you see condensation on windows or walls, turn the humidifier down, move it, or run it less. A hygrometer or a smart temperature and humidity sensor takes the guesswork out; check your reading with the indoor humidity checker, and see why 30–50% matters for the bigger picture.

Placement and everyday safety

  • Set the unit on a flat, water-safe surface a little way off the floor, away from wood furniture, electronics and bedding that a fine mist could dampen.
  • Keep warm mist and steam units out of children's reach; the EPA notes the burn risk from steam and hot water.
  • Don't let the area around the humidifier get damp; lower the output or run it intermittently.
  • If a unit won't be used for a few days, empty it and let the wick and tank dry out, as Honeywell's manual advises.
  • If a cool mist humidifier is for a large open area, consider an evaporative model, which avoids white dust and doesn't need distilled water.

The EPA notes that young children, older adults and people with lung conditions or allergies may be more sensitive to airborne contaminants, and advises stopping use and seeking medical advice if symptoms seem related to a humidifier.

See all humidifiers and supplies → To size a new one, see what size humidifier you need.

Sources: US EPA, Use and Care of Home Humidifiers; US CPSC publication 5046; Honeywell HEV620 owner's manual; Aprilaire replacement parts.

Related guides

Indoor humidity: why 30–50% matters and how to get thereMeasure first, then act on the number: what to do when indoor humidity reads below 30%, between 30 and 50%, or above 50 to 60%, from EPA and CPSC guidance.
Tower fan, pedestal or air circulator: choosing a fanTower, circulator, pedestal or ceiling fan: what each is good for, how to read CFM, watts and decibels on a listing, and when a fan stops helping.
Air purifier basics: HEPA, CADR and room sizeHow to read an air purifier listing: what True HEPA means, how to size by smoke CADR instead of the maker's room size, what carbon filters do, and what to avoid. From EPA and AHAM.
What size humidifier do you need? Output, coverage and tank size explainedWhy gallons per day matters more than tank size, a rule of thumb for square footage and ceiling height, what real models are rated for, and how to tell if a humidifier is too small or too big.